All
18
Building Permits
16
Planning
2
  • Plan: #P18-063
    The Retreat at Sacramento (P Files)

    In Progress
    Description:
    Request to construct a 224 unit, 736 bed, student housing facility with 525 parking spaces on a 13.3-acre property within the Residential Mixed Use, Light Industrial, and Transit Overlay zones (RMX-TO and M-1-TO). The request requires Planning and Design Commission review of a Conditional Use Permit for dormitories and Site Plan and Design Review for the new buildings.
    Attachments:

    2601_Redding-Ave_APP

    2601_Redding-Ave_PLANS

    P18-063_PLANS-REV1


    Contact:
    Michael Hanebutt
    916-808-7933
    Last Updated: Sep 18, 2018
    Application Submittal
    Ready for Review
    to receive an email alert when the next activity occurs
  • Permit: #COM-1816903
    Demolition (Commercial Demolition)

    Finaled
    Description:
    Demolish freestanding 100,000 gallon elevated water tan.
    Last Updated: Aug 31, 2018

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Finaled

    Inspection

    29 Bldg FINAL
    Approved
    to receive an email alert when the next activity occurs
  • Permit: #COM-1715874
    Fire Alarm Communicat\or (Office (Commercial Fire Equipment)

    Expired Permit
    Description:
    Installing radio communicator and connecting to the existing monitored fire alarm system.
    Last Updated: Sep 20, 2017

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Permit Expired
    Due Date: Aug 31, 2017

    Comments

    Mar 20, 2018
    Task completed by batch script BuildingPermitExpiration
    Last Updated: 2018-03-21 05:02:55 UTC

    Inspection

    100 Fire Alarm System
    Approved

    History:
    Sep 15, 2017
    Scheduled
    Sep 19, 2017
    Approved
    Last Updated: 2017-09-21 05:25:56 UTC
    100.1 Battery Test
    Approved

    History:
    Sep 15, 2017
    Scheduled
    Sep 19, 2017
    Approved
    Last Updated: 2017-09-21 05:25:57 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1715876
    Fire Alarm Communicat\or (Shop Building) (Commercial Fire Equipment)

    Expired Permit
    Description:
    Installing radio communicator and connecting to the existing monitored fire alarm system.
    Last Updated: Oct 16, 2017

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Permit Expired
    Due Date: Aug 31, 2017

    Comments

    Apr 15, 2018
    Task completed by batch script BuildingPermitExpiration
    Last Updated: 2018-04-16 05:01:56 UTC

    Inspection

    100 Fire Alarm System
    Approved

    History:
    Sep 15, 2017
    Scheduled
    Sep 19, 2017
    Approved
    Last Updated: 2018-04-16 05:01:56 UTC
    100.1 Battery Test
    Approved

    History:
    Sep 15, 2017
    Scheduled
    Sep 19, 2017
    Approved
    Last Updated: 2017-09-21 05:25:59 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1711082
    Fire Alarm (Commercial Fire Equipment)

    Expired Permit
    Description:
    Installing radio communicator and connecting to the existing monitored fire alarm system.
    Last Updated: Jul 31, 2017

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Permit Expired
    Due Date: Jun 26, 2017

    Comments

    Jan 28, 2018
    Task completed by batch script BuildingPermitExpiration
    Last Updated: 2018-01-29 05:01:52 UTC

    Inspection

    100 Fire Alarm System
    Approved

    History:
    Jul 12, 2017
    Scheduled
    Jul 12, 2017
    Rescheduled
    Jul 17, 2017
    Scheduled
    Jul 19, 2017
    Approved
    Last Updated: 2017-07-26 07:16:46 UTC
    194 Fire FINAL
    Approved

    History:
    Jul 12, 2017
    Scheduled
    Jul 12, 2017
    Rescheduled
    Jul 17, 2017
    Scheduled
    Jul 19, 2017
    Approved
    Last Updated: 2017-08-01 05:21:07 UTC
    100.1 Battery Test
    Approved

    History:
    Jul 12, 2017
    Scheduled
    Jul 12, 2017
    Rescheduled
    Jul 17, 2017
    Scheduled
    Jul 19, 2017
    Approved
    Last Updated: 2017-07-26 07:16:49 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1512264
    Commercial Reroof

    Finaled
    Description:
    Tear Off - No, Resheet - No, 2 layer(s), 100 squares of 30yr Laminated Dimensional Composition. In-progress inspection required if 10 squares or greater.
    Last Updated: Sep 3, 2015
    Application Submitted
    Approved Over the Counter

    Inspection

    83 Bldg-Roof In Progress
    Approved

    Inspector's Comments

    Sep 14, 2015
    Last Updated: 2015-09-14 12:13:50 UTC
    29 Bldg FINAL
    Approved

    Inspector's Comments

    Sep 28, 2015
    Last Updated: 2015-09-28 11:48:51 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1500336
    Commercial Reroof

    Finaled
    Description:
    REROOF 1/2 (EAST SIDE)Tear Off - No, Resheet - No, OVERLAY 1 layer(s), 120 squares of 30yr Laminated Dimensional Composition. In-progress inspection required if 10 squares or greater.
    Last Updated: Jan 8, 2015

    Inspection

    83 Bldg-Roof In Progress
    Approved

    History:
    Jan 13, 2015
    Scheduled
    Jan 26, 2015
    Approved

    Inspector's Comments

    Jan 13, 2015
    **SCHED INSPECTION THRU AUTOMATED LINE FOR TUES BUT SYSTEM GAVE HIM APPT FOR WED INSTEAD, CALLER REQUESTING AM INSPECTION IF POSSIBLE** PLEASE CALL FIRST

    Jan 26, 2015
    **SCHED INSPECTION THRU AUTOMATED LINE FOR TUES BUT SYSTEM GAVE HIM APPT FOR WED INSTEAD, CALLER REQUESTING AM INSPECTION IF POSSIBLE** PLEASE CALL FIRST
    Last Updated: 2015-01-26 17:19:03 UTC
    29 Bldg FINAL
    Approved

    Inspector's Comments

    Jan 30, 2015
    Last Updated: 2015-01-30 10:38:12 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1412549
    Commercial Remodel

    Finaled
    Description:
    EXPEDITED - REMODEL TEMP GENERATOR 70 KW
    Last Updated: Oct 10, 2014
    Tech Review
    Approved Over the Counter

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Finaled

    Inspection

    79 Elect FINAL
    Approved
    to receive an email alert when the next activity occurs
  • Permit: #COM-1410630
    Commercial Repair-Maintenance

    Finaled
    Description:
    EXPEDITED - INSTALL 200AMP 3PHASE SERVICE PANEL, 4 NEW 70AMP SINGLE PHASE FEEDERS, ONE TO EACH OF THE FOUR EXISTING BREAKER PANELS ON TWO MODULAR BUILDINGS FOR CONSTRUCTION USE.
    Last Updated: Aug 27, 2014
    Tech Review
    Approved Over the Counter

    Comments

    Aug 27, 2014
    APP OTC BY MKS
    Last Updated: 2014-10-23 01:50:58 UTC

    Permit Issuance

    Processing Permit
    Ready-to-Issue

    Comments

    Aug 27, 2014
    APP OTC BY MKS
    Last Updated: 2016-12-12 01:05:34 UTC
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Finaled

    Inspection

    79 Elect FINAL
    Approved

    History:
    Sep 9, 2014
    Correction Notice
    Sep 12, 2014
    Approved

    Inspector's Comments

    Sep 9, 2014
    2014-09-09
    Marc J Busig
    1) Drive 2 ground rod minimum 8' Drive at 45

    2) Provide working clearance at panel in back

    Sep 12, 2014
    2014-09-12
    Kim L Hagen
    per correction noitce, portable buildings should have had a different address. due to south of 4th ave location.
    Last Updated: 2014-10-23 01:51:00 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1407056
    Commercial New Building

    Expired Permit
    Description:
    EXPEDITED - New Trailer, 960 sq. ft. One set of plans for both permits. No sewer or water hookup. Expedited Review 10, 5, 5, - PLNG-INSP, Plans Shared with COM-1407046
    Last Updated: Jun 11, 2014
    Tech Review
    Triage Not Required

    Review

    Fire Review
    Cycle 1 Approved
    Development Engineering Review
    Cycle 1 Approved
    Planning Review
    Cycle 1 Approved

    Plan Review Comments

    Jul 7, 2014
    Approved Per IR14-083.
    Last Updated: 2014-10-23 04:09:04 UTC
    Utilities Review
    Cycle 2 Approved

    History:
    Jun 30, 2014
    Cycle 1 Correction
    Jul 11, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:09:02 UTC
    Landscape Architect
    Cycle 2 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 17, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:09:03 UTC
    Structural Review
    Cycle 1 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 1 Approved
    Last Updated: 2014-10-23 04:09:00 UTC
    Plumbing
    Cycle 1 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 1 Approved
    Last Updated: 2014-10-23 04:09:01 UTC
    Electrical Review
    Cycle 2 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:09:01 UTC
    Review Begin
    Cycle 3 Begin

    History:
    Jun 20, 2014
    Cycle 1 Begin
    Jul 10, 2014
    Cycle 2 Begin
    Jul 22, 2014
    Cycle 3 Begin
    Last Updated: 2014-10-23 04:09:00 UTC
    Life Safety Review
    Cycle 2 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 2 Correction
    Jul 24, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:09:04 UTC
    Formal Review
    Approved

    Plan Review Comments

    Jul 24, 2014
    Formal Review Subtasks Complete - Script2
    Last Updated: 2014-10-23 04:08:58 UTC

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Temporary Certificate of Occupancy Issued
    Issued
    Permit Expired

    Comments

    Apr 20, 2015
    Task completed by batch script BuildingPermitExpiration
    Last Updated: 2015-04-20 03:00:01 UTC

    Inspection

    59 Plmg FINAL
    Approved

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Charles Sherman
    OK to apply for TCO upon the approval of others.
    Last Updated: 2014-10-23 04:09:09 UTC
    194 Fire FINAL
    Approved

    Inspector's Comments

    Oct 3, 2014
    2014-10-03
    Jeff Mogler
    Approved fire final and signed both permit folders.
    Last Updated: 2014-10-23 04:09:09 UTC
    89 Planning FINAL
    Approved

    History:
    Sep 23, 2014
    Cancelled
    Oct 9, 2014
    Approved

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Robert W Williams
    Job Copy was not available onsite. Reschedule inspection when job copy is available for inspector to review, this includes the job card.
    Last Updated: 2014-10-23 04:09:08 UTC
    79 Elect FINAL
    Partially Approved

    History:
    Sep 23, 2014
    Cancelled
    Oct 9, 2014
    Correction Notice
    Oct 10, 2014
    Cancelled
    Oct 13, 2014
    Partially Approved

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Kim L Hagen
    by phone.

    Oct 9, 2014
    2014-10-09
    Marc J Busig
    1) Revise plans to include the generator providing temp power until SMUD is connected. Revise plans must be approved prior to TCO being approved

    Oct 13, 2014
    2014-10-13
    Marc J Busig
    OK to apply for TCO when others approve
    Last Updated: 2014-10-23 04:09:07 UTC
    29 Bldg FINAL
    Correction Notice

    History:
    Sep 23, 2014
    Not Ready
    Oct 3, 2014
    Rescheduled
    Oct 3, 2014
    Inspector Locked Out (no inspection)
    Oct 6, 2014
    Correction Notice
    Oct 9, 2014
    Not Ready
    Oct 10, 2014
    Rescheduled
    Oct 14, 2014
    Cancelled
    Oct 15, 2014
    Correction Notice
    Oct 21, 2014
    Correction Notice

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Josh Pino
    No approved plans @ site. Reviewed disabled access requirements w/ personnel @ site.

    Oct 3, 2014
    2014-10-03
    Josh Pino
    Called phone number on inspection request approx. 45 mins. prior to visiting site. I received no return call & was locked out when I arrived.

    Oct 6, 2014
    2014-10-06
    Charlie E Donahue
    Called @ 1158 hrs prior to arrival.

    1. Install (2) 5/8" carriage bolts 16" o.c. ledger to trailor per plan.

    2. Stair treads to be minimum 11". Stair risers to be 4" minimum & 7" max. Risers shall be solid. Recut stringers.

    3. Handrail to slope one tread width past botton riser then horizontal 12" w/ ends returned so as not to catch shirt sleeve on.

    4. Provide electrical & planning finals.

    Oct 9, 2014
    2014-10-09
    Charlie E Donahue
    Called @ 0805 & 0958 hrs prior to arrival. Arrived around 1015 hrs.

    1. No other disciplines approved yet.

    2. The reconstruction of the stairway is just beginning and the carriage bolts have not yet been installed at the door landings. Advised contact at site to recall inspection.

    Oct 15, 2014
    2014-10-15
    Charlie E Donahue
    Called @ 0853 hrs prior to arrival.

    1. Per the previous c/n treads required to be minimum 11" per 2013 CBC section 1009.7.2 as follows. Riser height and tread depth. Stair riser heights shall be 7 inches (178 mm) maximum and 4 inches (102 mm) minimum. The riser height shall be measured vertically between the nosings of adjacent treads. Rectangular tread depths shall be 11 inches (279 mm) minimum measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's nosing.

    2. The 2x10 ledger board at the landings supporting the perpendicular floor joist have been installed with the carriage bolts without nuts & washers on the back side. Additionally their is nothing to attach the ledger to other than the 1/2 plywood skirt board and the plans do not show any detail for attachment. Please provide an alternate detail from the a.o.r. and submit to the city plan review for approval.

    3. Provide tow away co name and phone number on the entrance tow away sign.

    4. Provide approvals from other disciplines.

    THIS APPLIES TO PER COM- 1407046 AS WELL.

    Oct 21, 2014
    2014-10-21
    Paul W Clayton
    Inspection performed for reinspection of previous correction notice.

    Ok for TCO with all other required approvals. Building final not to be finaled until other required diisciplines final.
    Last Updated: 2014-10-23 04:09:06 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1407046
    Commercial New Building

    Expired Permit
    Description:
    EXPEDITED - New trailer, 24' x 44', 1056 sq. ft. One set of plans for both permits. No sewer or water hookup. Expedited Review 10, 5, 5, - PLNG-INSP, Plans shared with COM-1407056
    Last Updated: Jun 11, 2014
    Tech Review
    Triage Not Required

    Review

    Fire Review
    Cycle 1 Approved
    Development Engineering Review
    Cycle 1 Approved

    Plan Review Comments

    Jul 2, 2014
    2 trailers were submitted in 2 permits. COM-1407056 is approved separately.
    Last Updated: 2014-10-23 04:08:45 UTC
    Planning Review
    Cycle 1 Approved

    Plan Review Comments

    Jul 7, 2014
    Approved Per IR14-083.
    Last Updated: 2014-10-23 04:08:46 UTC
    Utilities Review
    Cycle 2 Approved

    History:
    Jun 30, 2014
    Cycle 1 Correction
    Jul 11, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:08:45 UTC
    Landscape Architect
    Cycle 2 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 17, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:08:46 UTC
    Structural Review
    Cycle 1 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 1 Approved
    Last Updated: 2014-10-23 04:08:44 UTC
    Plumbing
    Cycle 1 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 1 Approved
    Last Updated: 2014-10-23 04:08:44 UTC
    Electrical Review
    Cycle 2 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:08:45 UTC
    Review Begin
    Cycle 3 Begin

    History:
    Jun 20, 2014
    Cycle 1 Begin
    Jul 10, 2014
    Cycle 2 Begin
    Jul 22, 2014
    Cycle 3 Begin
    Last Updated: 2014-10-23 04:08:44 UTC
    Life Safety Review
    Cycle 2 Approved

    History:
    Jul 7, 2014
    Cycle 1 Correction
    Jul 21, 2014
    Cycle 2 Correction
    Jul 24, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 04:08:46 UTC
    Formal Review
    Approved

    Plan Review Comments

    Jul 24, 2014
    Formal Review Subtasks Complete - Script2
    Last Updated: 2014-10-23 04:08:42 UTC

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Temporary Certificate of Occupancy Issued
    Issued
    Permit Expired

    Comments

    Apr 20, 2015
    Task completed by batch script BuildingPermitExpiration
    Last Updated: 2015-04-20 03:00:01 UTC

    Inspection

    59 Plmg FINAL
    Approved

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Charles Sherman
    OK to apply for the TCO upon the approval of others.
    Last Updated: 2014-10-23 04:08:51 UTC
    194 Fire FINAL
    Approved

    Inspector's Comments

    Oct 3, 2014
    2014-10-03
    Jeff Mogler
    Approved fire final and signed both permit folders.
    Last Updated: 2014-10-23 04:08:51 UTC
    89 Planning FINAL
    Approved

    History:
    Sep 23, 2014
    Cancelled
    Oct 9, 2014
    Approved

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Robert W Williams
    Job Copy was not available onsite. Reschedule inspection when job copy is available for inspector to review, this includes the job card.
    Last Updated: 2014-10-23 04:08:50 UTC
    79 Elect FINAL
    Partially Approved

    History:
    Sep 23, 2014
    Cancelled
    Oct 9, 2014
    Correction Notice
    Oct 10, 2014
    Cancelled
    Oct 13, 2014
    Partially Approved

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Kim L Hagen
    by phone, no plans on site.

    Oct 9, 2014
    2014-10-09
    Marc J Busig
    1) Revise plans to include the generator providing temp power until SMUD is connected. Revise plans must be approved prior to TCO being approved

    Oct 13, 2014
    2014-10-13
    Marc J Busig
    OK to apply for TCO when others approve
    Last Updated: 2014-10-23 04:08:49 UTC
    29 Bldg FINAL
    Correction Notice

    History:
    Sep 23, 2014
    Not Ready
    Oct 3, 2014
    Rescheduled
    Oct 3, 2014
    Inspector Locked Out (no inspection)
    Oct 6, 2014
    Correction Notice
    Oct 9, 2014
    Not Ready
    Oct 10, 2014
    Rescheduled
    Oct 14, 2014
    Rescheduled
    Oct 14, 2014
    Cancelled
    Oct 15, 2014
    Correction Notice
    Oct 21, 2014
    Correction Notice

    Inspector's Comments

    Sep 23, 2014
    2014-09-23
    Josh Pino
    No approved plans @ site. Reviewed disabled access requirements w/ personnel @ site.

    Oct 3, 2014
    2014-10-03
    Josh Pino
    Called phone number on inspection request approx. 45 mins. prior to visiting site. I received no return call & was locked out when I arrived.

    Oct 6, 2014
    2014-10-06
    Charlie E Donahue
    Called @ 1158 hrs prior to arrival.

    1. Install (2) 5/8" carriage bolts 16" o.c. ledger to trailor per plan.

    2. Stair treads to be minimum 11". Stair risers to be 4" minimum & 7" max. Risers shall be solid. Recut stringers.

    3. Handrail to slope one tread width past botton riser then horizontal 12" w/ ends returned so as not to catch shirt sleeve on.

    4. Provide electrical & planning finals.

    Oct 9, 2014
    2014-10-09
    Charlie E Donahue
    Called @ 0805 & 0958 hrs prior to arrival. Arrived around 1015 hrs.

    1. No other disciplines approved yet.

    2. The reconstruction of the stairway is just beginning and the carriage bolts have not yet been installed at the door landings. Advised contact at site to recall inspection.

    Oct 15, 2014
    2014-10-15
    Charlie E Donahue
    Called @ 0853 hrs prior to arrival.

    1. Per the previous c/n treads required to be minimum 11" per 2013 CBC section 1009.7.2 as follows. Riser height and tread depth. Stair riser heights shall be 7 inches (178 mm) maximum and 4 inches (102 mm) minimum. The riser height shall be measured vertically between the nosings of adjacent treads. Rectangular tread depths shall be 11 inches (279 mm) minimum measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's nosing.

    2. The 2x10 ledger board at the landings supporting the perpendicular floor joist have been installed with the carriage bolts without nuts & washers on the back side. Additionally their is nothing to attach the ledger to other than the 1/2 plywood skirt board and the plans do not show any detail for attachment. Please provide an alternate detail from the a.o.r. and submit to the city plan review for approval.

    3. Provide tow away co name and phone number on the entrance tow away sign.

    4. Provide approvals from other disciplines.

    THIS APPLIES TO PER COM- 1407046 AS WELL.

    Oct 21, 2014
    2014-10-21
    Paul W Clayton
    Inspection performed for reinspection of previous correction notice.

    Ok for TCO with all other required approvals. Building final not to be finaled until other required diisciplines final.
    Last Updated: 2014-10-23 04:08:49 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1402395
    Commercial Other Struct (non-bldg)

    Finaled
    Description:
    Install new 75' billboard sign.
    Last Updated: Feb 28, 2014
    Tech Review
    Triage Not Required

    Review

    Planning Review
    Cycle 1 Approved

    Plan Review Comments

    Mar 7, 2014
    No planning or design review issues.
    Last Updated: 2014-10-23 01:41:41 UTC
    Utilities Review
    Cycle 1 Approved

    Plan Review Comments

    Mar 17, 2014
    I placed an erosion and sediment control note on sheet E1. I also provided a second note with this plan set.
    Last Updated: 2014-10-23 01:41:41 UTC
    Life Safety Review
    No Review Required
    Structural Review
    Cycle 2 Approved

    History:
    Mar 21, 2014
    Cycle 1 Correction
    Apr 11, 2014
    Cycle 2 Approved
    Last Updated: 2014-10-23 01:41:41 UTC
    Development Engineering Review
    Cycle 2 Approved

    History:
    Mar 19, 2014
    Cycle 1 Correction
    Apr 16, 2014
    Cycle 2 Approved

    Plan Review Comments

    Mar 19, 2014
    Plan to show dimensions at where the proposed sign will be installed. North property line shows 168.92'. Assessor map shows 156.49'.
    Last Updated: 2014-10-23 01:41:41 UTC
    Review Begin
    Cycle 3 Begin

    History:
    Feb 28, 2014
    Cycle 1 Begin
    Apr 2, 2014
    Cycle 2 Begin
    Apr 25, 2014
    Cycle 3 Begin
    Last Updated: 2014-10-23 01:41:41 UTC
    Electrical Review
    Cycle 3 Approved

    History:
    Mar 21, 2014
    Cycle 1 Correction
    Apr 16, 2014
    Cycle 2 Correction
    May 5, 2014
    Cycle 3 Approved
    Last Updated: 2014-10-23 01:41:42 UTC
    Formal Review
    Approved

    Plan Review Comments

    May 5, 2014
    Formal Review Subtasks Complete - Script2
    Last Updated: 2014-10-23 01:41:40 UTC

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Finaled

    Inspection

    60 Elect-Concrete Encased Electrode (Ufer)
    Approved

    Inspector's Comments

    Jun 2, 2014
    2014-06-02
    Charlie E Donahue
    Called @ 1217 hrs prior to arrival.

    1. Ufer at pole and meter.
    Last Updated: 2014-10-23 01:41:44 UTC
    10 Bldg-Foundation Forms
    Approved

    Inspector's Comments

    Jun 2, 2014
    2014-06-02
    Charlie E Donahue
    Called @ 1217 hrs prior to arrival.

    1. Ufer at pole and meter.
    Last Updated: 2014-10-23 01:41:44 UTC
    79 Elect FINAL
    Approved
    89 Planning FINAL
    Approved
    29 Bldg FINAL
    Approved

    History:
    Jul 8, 2014
    Correction Notice
    Jul 9, 2014
    Approved

    Inspector's Comments

    Jul 8, 2014
    2014-07-08
    Charlie E Donahue
    Called @ 1021 hrs prior to arrival.

    1. Picked up daily special inspection reports but still need the FINAL SPECIAL INSPECTION LETTER.

    2. Provide a planning site final. Call in for a number 89 final.
    Last Updated: 2014-10-23 01:41:43 UTC
    to receive an email alert when the next activity occurs
  • Plan: #P13-059
    Sign Relocation for 2601 Redding Avenue (P Files)

    Approved
    Description:
    A request to remove three existing signs at various locations with a total sign area of 1,500 square feet and construct one double sided, 1,344 square foot off-site sign for a 156 square foot net reduction of display area. The new sign is proposed to be located at 2601 Redding Avenue on 0.10 acres. The project requires a General Plan Amendment from Urban Neighborhood Low Density to Employment Center Low Rise, a Rezone from Residential Mixed Use Transit Overlay (RMX-TO) to Light Industrial (M-1), a Relocation Agreement to remove three existing signs with a total of 1,500 square feet, a Variance to allow a new sign that is 80 feet in height, and Site Plan and Design Review to construct one double-sided 1,344 square foot offsite sign.

    Contact:
    Evan Compton
    916-808-5260
    Last Updated: Oct 18, 2013
    Application Submittal
    Ready for Review

    Comments

    Oct 18, 2013
    Put on Greg's chair.
    Last Updated: 2016-12-14 14:03:14 UTC
    Planning Review
    Approved

    History:
    Oct 22, 2013
    Note
    Oct 28, 2013
    Note
    Nov 7, 2013
    Email
    Nov 22, 2013
    Staff Report
    Dec 11, 2013
    Internal Review/Meeting
    Jan 10, 2014
    Internal Review/Meeting
    Jan 23, 2014
    Staff Report
    Jan 30, 2014
    Hearing
    Feb 18, 2014
    Internal Review/Meeting
    Feb 18, 2014
    Hearing
    Feb 25, 2014
    Hearing
    Mar 11, 2014
    Note
    Mar 11, 2014
    Approved

    Plan Review Comments

    Oct 22, 2013
    File assigned.

    Oct 28, 2013
    Reviewed application and sent applicant an email requesting additional information and exhibit showing the billboards to be removed.

    Nov 7, 2013
    Email regarding opposition with neighbor.

    Nov 22, 2013
    Week of 11/18 to 11/22: Working on report draft, presentation at MRC, and emails.

    Dec 11, 2013
    analysis

    Feb 18, 2014
    pfp

    Mar 11, 2014
    Hours from Principal Planner, Greg Bitter for project related duties.

    Mar 11, 2014
    Entitlements approved by City Council on February 25, 2014.
    Last Updated: 2016-12-14 14:03:15 UTC
    to receive an email alert when the next activity occurs
  • Permit: #COM-1311540
    Commercial Remodel

    Finaled
    Description:
    EXPEDITED - KNOX BOX, FIRE DEPT DOOR OPENER KEY PAD
    Last Updated: Sep 30, 2013
    Tech Review
    Approved Over the Counter

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work
    Issued
    Finaled

    Inspection

    194 Fire FINAL
    Approved

    Inspector's Comments

    Sep 30, 2013
    2013-10-22
    Carrie Johnson
    Tested and verified Click 2 Enter and functionality of vehicle key switch. Both passed.
    Last Updated: 2014-10-24 07:51:06 UTC
    701 Knox Box
    Approved

    Inspector's Comments

    Oct 21, 2013
    2013-10-22
    Carrie Johnson
    Tested and verified Click 2 Enter and functionality of vehicle key switch. Both passed.
    Last Updated: 2014-10-24 07:51:06 UTC
    29 Bldg FINAL
    Cancelled

    Inspector's Comments

    Jan 15, 2014
    2014-01-15
    Charlie E Donahue
    wrong discipline. Called contact and advised to schedule E79 inspection.
    Last Updated: 2014-10-24 07:51:06 UTC
    79 Elect FINAL
    Approved
    to receive an email alert when the next activity occurs
  • Permit: #COM-0812742
    Building/Commercial/Repair-Maintenance/Industrial

    Finaled
    Description:
    INSTALL NEW CONDUIT & WIRE FOR NEW 600 AMP DISTRIBUTION PANEL
    Last Updated: Sep 23, 2008
    Tech Review
    Approved Over the Counter

    Comments

    Sep 29, 2008
    Approved OTC by CDY
    Last Updated: 2014-10-26 05:59:05 UTC

    Permit Issuance

    Processing Permit
    Ready-to-Issue
    Ready To Issue
    Permit Issued; applicant can begin work

    Inspection

    61 Elect-Conduit/Underground
    Approved

    Inspector's Comments

    Oct 3, 2008
    2008-10-03
    Mark S Koslosky
    3 - 2 1/2" co
    Last Updated: 2014-10-26 05:59:08 UTC
    79 Elect FINAL
    Approved
    to receive an email alert when the next activity occurs
  • Permit: #0513143
    IR05-397 (Building/Commercial/Housing-Minor/Other Non-Res Bldgs)

    Finaled
    Description:
    F050032462--DEMOLITIONOF AN INDUSTRIAL STORAGE SHED THAT HAS PARTIALLY COLLAPSED AND BEEN DEEMED IMMEDIATELY HAZARDOUS.
    Last Updated: Aug 29, 2005

    Inspection

    Bldg-Shear Nail
    Approved
    Bldg-Roof Plywood Nailing
    Partially Approved

    Inspector's Comments

    Dec 30, 2005
    2005-12-30
    LAD
    OK ROOF SHEATHING OVER WEST (3) BAYS ONLY. OK TO COVER.
    Last Updated: 2014-10-29 00:04:37 UTC
    Bldg-Foundation Forms
    Approved

    History:
    Jan 6, 2006
    Approved
    Feb 15, 2006
    Approved
    Mar 16, 2006
    Approved

    Inspector's Comments

    Jan 6, 2006
    2006-01-06
    LAD
    NORTH WALL LINE ONLY

    Feb 15, 2006
    2006-02-15
    LAD
    APPROVED 1ST PHASE OF FOOTINGS FOR LOADING DOCK REVISION, NEEDS DRY PACK INSP PROIR TO PLACING CONCRETE FOR 2ND POUR.

    Mar 16, 2006
    2006-03-16
    LAD
    APPROVED DRY PACK UNDER COLUMNS. OK TO COMPLETE CONCRETE POUR OF FOOTINGS FOR LOADING DOCK.

    ALSO APPROVED STRAP TIES FOR NORTH WALL AT PLATE LINE.
    Last Updated: 2014-10-29 00:04:37 UTC
    Bldg-FINAL
    Approved
    to receive an email alert when the next activity occurs
  • Permit: #0116002
    Building/Commercial/Minor/Office

    Finaled
    Description:
    TEAR OFF & REROOF 8 SQS WITH B.U./SMOOTH ROOFING
    Last Updated: Dec 20, 2001

    Inspection

    Bldg-FINAL
    Approved
    to receive an email alert when the next activity occurs
  • Permit: #R5925
    Building/Archive/Archive/Retail Store

    Finaled
    Description:
    Electrical meter box repair
    Last Updated: Aug 5, 1988
    to receive an email alert when the next activity occurs

No results